FAQ

Can I use my Sparklike Handheld™ 3.0 device to measure laminated glass?

Yes — Sparklike Handheld™ can measure through laminated glass, but only under certain conditions.

Here’s what you need to know for a successful measurement:

  • The laminated glass should be thin, typically 1 or 2 interlayers of 0.38 mm each
  • Ideal total glass thickness: 3+3 mm or 4+4 mm with one interlayer
  • Higher gas fill rates improve spark penetration through laminated glass
  • Always measure next to the spacer, as recommended for best accuracy
  • The spark must be visible during the measurement — this remains a key requirement

Sparklike Handheld™ uses non-invasive Spark Emission Spectroscopy to verify gas fill without damaging the IGU, making it possible to check gas concentration even in certain laminated constructions.

Note: Laminated units that exceed the recommended thickness or have multiple interlayers may not yield reliable results. If in doubt, contact Sparklike support for guidance.